Heraeus FT6060 explosiebeveiligde droogstoof 52 liter 105°C
Art.Nr.
L0150035800

Heraeus FT6060 explosiebeveiligde droogstoof 52 liter 105°C

Art.Nr.
L0150035800

Volume: 52 liter
Temperatuurbereik: KT+5 tot 105°C
Behuizing (bxhxd): 600 x 794 x 640mm
Binnenmaat (bxhxd): 400 x 380 x 340 cm
Opwarmtijd: 50 min
Vermogen: 1300 W
Gewicht: 92 kg
Voor explosiegevaarlijke oplosmiddelen
Wordt geleverd met 2 inlegbladen

For solvents of temperature classes T1, T2, T3 and T4
Bekijk alle specificaties
Specificaties
Specificaties
Merk Heraeus - Thermo
Volume 52 liter
Max. Temperatuur 105
Productbeschrijving

Heraeus FT6060 explosiebeveiligde droogstoof 52 liter 105°C

  • explosie beschermde droogoven
  • Designed for solvents of temperature classes T1, T2, T3 and T4
  • Unrestricted quantities of solvent
  • Nominal temperature up to 105 °C
  • Straightforward operation thanks to clearly arranged operator control elements

The chemical and pharmaceutical industries, the dyestuff, varnish,lacquer and paint industries, the process manufacturing sector and a large number of other industries are dependent on heat treatment processes, in which combustible solvents are released, which can produce potentially explosive mixtures when they come into contact with air. We have developed a new oven specially designed to handle the requirements of these sectors – the FT 6060 fresh-air laboratory oven.

The FT 6060 prevents the build-up of hazardous conditions during heat treatment and the associated danger to the operating personnel and equipment. Unlike other ovens currently available on the market, which are only capable of handling limited amounts of solvent, the solvent-processing capacity of the FT 6060 knows no limits. This means that the FT 6060 offers a much higher degree of safety in day-to-day routine operations.

Wide range of possible applications

The FT 6060 can be installed in all research, development and application laboratories where combustible solvents of temperature classes T1, T2, T3 and T4 as well as explosion classes IIA and IIB are used, or where such solvents are released in unknown quantities when material is being dried. The dangers involved in the various applications are frequently underestimated or are simply unknown. Every laboratory should attach particular importance to checking the safety precautions implemented for the respective application. The FT 6060 covers a wide range of danger classes comfortably and therefore offers an ideal solution for all hazardous applications.The straightforward arrangement of the control elements in the switching unit enables particularly safe and easy operation.
Accessoires
Downloads
  • Hoge kwaliteit en uitgebreide service
  • Al meer dan 100 jaar een begrip
  • Een breed assortiment
Scroll to top