Sonation SSH56-42U box waterkoelers 500x730x765mm 16A APPS
Art.Nr.
L285SSH56-42U

Sonation SSH56-42U box waterkoelers 500x730x765mm 16A APPS

Art.Nr.
L285SSH56-42U

Geschikt voor de geluidsdemping van waterkoelers et APPS (Aktief pomp protectie systeem)
Interne monitoring van de temperatuur met alarm bij hoge temperatuur.

Ventilatorsnelheden worden elektronisch aangepast aan de temperatuur.
Geluidsreductie tot 16 dB
Afmeting intern (bxdxh) 500 x 765 x 730 mm

Afmeting extern (bxdxh) 540 x 880 x 750 mm
Gewicht 33 kg

Bekijk alle specificaties
Specificaties
Specificaties
Merk Sonation
Afscheider zuigzijde Nee
Condenser uitlaat Nee
Productbeschrijving

Sonation SSH56-42U box waterkoelers 500x730x765mm 16A APPS

The model SSH56 was developed especially for the ThermoFlex 900 water cooler of the ThermoFlex series. It is also suitable for similar models.

Versions and order codes:

Models with APPS:

SSH56-41U
- Temperature monitoring with alarm
- Two temperature controlled fans with speed monitoring
- IEC 10A (C13) power outlet inside the box with current monitoring and emergency shutdown to power the vacuum pump
- IEC 10A (C14) power socket to connect the box to your MS or to a wall outlet
- Wide range input 100-250V AC (50/60 Hz)


Models without APPS:

SSH56-412 (former SSH56TF10A)
- Two fans for heat removal
- Connects to 230V AC (50/60Hz) mains
- IEC 10A (C14) power socket to connect the box to your MS or to a wall outlet
- IEC 10A (C13) power outlet inside the box to power the vacuum pump

SSH56-411 (former SSH56TF10A-115V)
- Two fans for heat removal
- Connects to 115V AC (50/60Hz) mains
- IEC 10A (C14) power socket to connect the box to your MS or to a wall outlet
- IEC 10A (C13) power outlet inside the box to power the vacuum pump

Specifications SSH56 noise reduction box

General data:

  • Exterior dimensions: 540 x 750 x 880 mm (WxHxD)
  • Interior dimensions: 500 x 730 x 765 mm (WxHxD)
  • Robust all-metal construction, powder coated in RAL 5012 light blue
  • Tough, washable, hygienic surface
  • High-grade insulant made of recycled material, oil and water repellent
  • Flammability in compliance with FMVSS 302 and DIN 75200, respectively
  • Ingenious air piping system for maximum heat elimination and optimal acoustic insulation
  • Achieves noise reduction of up to 16 dB
  • Easy installation
  • Easy access to the water cooler for servicing purposes

Models with APPS:

  • Connects to 100-250VAC 50/60 Hz
  • Temperature monitoring with alarm
  • Equipped with four temperature controlled and function monitored fans for ventilation
  • Airflow up to 640m³/h (380cfm), temperature controlled
  • Loads up to 10A can be connected to to inner power outlet. The power outlet is current controlled and equipped with an emergency shutdown.

Models without APPS:

  • Connects to 230V / 50 Hz (115V models on request), with 10A fine-wire fuse safety
  • Equipped with three fans with a combined airflow of 360m³/h (210cfm)
  • Integrated temperature display at the front

 

APPS the Active Pump Protection System

The newly developed APPS module (Active Pump Protection System) enables you to perfectly protect your sensitive and important devices by monitoring all important operating data. The pump is optimally protected with the new module, which fits and can be retrofitted to all Sonation sound insulation boxes. All important operating data, for example, temperature, current consumption and the function of the fans are monitored continuously. Any malfunction triggers a visual and acoustic warning.

Interior temperature monitoring with high temperature alarm
The interior temperature is continuously measured. When a threshold is exceeded
a visual and acoustic warning is triggered. If the temperature assumes
dangerous values due to a pump defect, the current supply to the pump is
interrupted to prevent consequential damage (can be switched off).

RealTemp
The measured temperature is the exhaust temperature and therefore represents the exact interiour temperature in the noise reduction box. Most of the other systems on the market measure the temperature near to the air intakes and show a too low temperature. This can significantly shorten the lifetime of the insulated pump.

Wide-range input
The sound insulation box can be operated on 115 V and 230 V networks.

Temperature controlled fans
The speed of the fans is only as high as is necessary to keep the pumps cool.
This will increase the service life of the fans and additionally lowers the noise
level.

Monitoring of the fans
If one or more fans fail or significantly lose output it is displayed visually and an
acoustic warning sounds. Thus the system monitors and detects age-related
wear, as well as the sudden total failure of a fan.

Monitoring pump current
Pump current is monitored if the pump is operated using the integrated power outlet.
If the current consumption exceeds a critical value over a long time period,
which can occur for example with a bearing failure, the current consumption is
interrupted in order to prevent total damage of the pump.
Connection to a PC

All values can be easily monitored on a PC using the optional software, and
can also be integrated and evaluated in third-party software via interfaces.

Retrofitting capability
All existing sound insulation boxes can be retrofitted with the APPS module.

Fans from noise insulation boxes without APPS should be replaced after about
3-4 years, since over time they continually lose cooling capacity.